hCG Rapid Test Cartridges - Lateral flow hCG

hCG Rapid Test Cartridges - Lateral flow hCG

£0.00

The  hCG Rapid Diagnostic Test is a qualitative, instrument-read, urine test for early detection of pregnancy. The test is performed on Smart Tester analyzers. Positive results are reported in as little as 3 minutes.

For Professional In Vitro Diagnostic Use Only.

Learn More

Add To Cart
Homepage > Products > POCT Rapid Test System > hCG Rapid Test Cassette

Features

Features & Functions

SmartTester hCG lateral flow rapid test kit detects hCG levels above 15 mIU/mL.

hCG Rapid Test is standardized to the World Health Organization 5th International Standard (NIBSC code: 07/364).

The hCG lateral flow Rapid Test and Smart Tester analyzers are CE marked IVD 98/79EC.

Sample Volume: 100ul (Urine)
Reaction Time: 5 minutes
Storage: 1 to 30°C
Shelf life: up to 24 months
Principle of the Rapid Diagnostic Test

The test uses an anti-hCG monoclonal antibody conjugated with colloidal gold and another anti-hCG monoclonal antibody coated on the test line. When the sample has been applied to the test cartridge, the gold-labelled anti-hCG monoclonal antibody binds with the hCG in sample and forms a marked antigen-antibody complex. This complex moves then to the test cartridge detection zone by capillary action where it is captured on the test line by the other anti-hCG monoclonal antibody, resulting in a purplish red colouring on the test line.

Kit Contents

hCG Test Kit Contents
  • 25 Lateral test hCG rapid test cassettes
  • 1 lot code cassette
  • 25 disposable capillary pipettes
  • 1 instruction for use

Performance Characteristics

SmartTester hCG lateral flow rapid test kit detects hCG levels above 15 mIU/mL. The kit is standardized to the World Health Organization 5th International Standard (NIBSC code: 07/364).

Sensitivity limit of the tests for hCG were assessed using urine samples of non-pregnant individuals spiked with Chorionic Gonadotrophin, (5th IS) to various hCG levels. Samples were tested with three different reagent lots and three different SmartTester instruments. The results of the sensitivity assessment are shown below.

  • 0 mIU/mL - 0 % Percent Positive [%]
  • 5 mIU/mL - 0 %
  • 10 mIU/mL - 28.3 %
  • 15 mIU/mL - 96.7 %
  • 20 mIU/mL - 100 %
  • 25 mIU/mL - 100 %
  • 30 mIU/mL - 100 %
  • 40 mIU/mL - 100 %
  • 50 mIU/mL - 100 %
  • 100 mIU/mL - 100 %

Specificity of hCG rapid tests were evaluated with homologous hormones human luteinizing hormone (LH), human follicule stimulating hormone (FSH) and human thyroid stimulating hormone (TSH). The presence of these hormones in the concentrations tested did not affect the test results.


Variants and Related Products

Variants and Related Products


STR-9911 SmartTester Reader 1 device
RTC-9901-1 CRP Cartridges 25 tests
RTC-9913-1 hCG Rapid Test Cartridges 25 tests
RTC-9902-1 D-Dimer Rapid Test Cartridges 25 tests
RTC-9911-1 Microalbumin Rapid test Cartridges 25 tests
RTC-9912-1 TSH Rapid Test Cartridges 25 tests
RTC-9903-1 Cardiac Troponin l (cTnI) Rapid Test cartridges 25 tests